• Home
  • Products
  • Reverse Osmosis (RO) Water Treatment Plant – 9000 GPD / 1500 LPH

Share:

[evercompare_button]

Reverse Osmosis (RO) Water Treatment Plant – 9000 GPD / 1500 LPH

Key Features

  • Model: WM-1500RO
  • Capacity: 9000 GPD
  • Purification Stage: Sand Filter / Carbon Filter / Softener (Resin) / Micron Filter / Reverse Osmosis (RO) / UV (Optional)
  • Membrane Type: RO Membrane
  • Vessel Material: FRP / SS / MS
  • High-Pressure Pump: SS Multistage
  • Operating: Manual / Semi-Automated / Fully Automated

Reverse Osmosis (RO) Water Treatment Plant 9000 GPD / 1500 LPH

Approx. Suitable for 2400–4800 Persons

Product Overview

This 9000 GPD (approximately 1500 LPH) RO Water Treatment Plant is engineered for locations where drinking water demand fluctuates heavily throughout the day, and a stable, high-output purification system is essential.

Instead of simply scaling up membrane count, this system emphasizes robust pre-treatment and flow stability, using a 20×72 (2072) FRP pressure vessel to handle higher inlet water loading. The larger vessel volume allows deeper filter media beds, ensuring consistent feed water quality, reduced pressure drop, and smoother long-hour operation.

The plant is ideally suited for industrial facilities, large mosques, residential labor housing, educational campuses, and public drinking water distribution points, serving approximately 2,400–4,800 users, depending on operating hours and per-person consumption.

Key Technical Specifications

  • Rated Output: 9000 GPD (≈ 1500 Liters Per Hour)

  • Intended Use: Drinking & cooking water

  • Coverage Capacity: Approx. 2400–4800 persons

  • Purification Technology: Reverse Osmosis (RO)

  • Pre-Treatment Vessel: FRP 20×72 (2072)

  • Salt (TDS) Rejection: Up to 95–98%

  • Typical Recovery: 40–50% (raw water dependent)

  • Operating Mode: Semi-automatic / Fully automatic

System Layout & Treatment Units

Pre-Treatment Section

  1. Raw Water Feed Pump

    • Ensures steady flow and adequate pressure to the filtration units

  2. Pressure Sand Filter – 2072 FRP Vessel

    • Removes turbidity, sand, silt, and suspended solids

  3. Activated Carbon Filter (ACF)

    • Removes chlorine, odor, color, and organic contaminants

    • Essential for RO membrane protection

  4. Micron Cartridge Filter (5–10 Micron)

    • Final fine filtration before RO membranes

RO Purification Section

  1. High-Pressure RO Pump

    • Supplies required pressure for membrane separation

  2. RO Membrane Housing with High-Rejection Membranes

    • Removes dissolved salts, heavy metals, bacteria, and viruses

  3. Pressure Gauges & Flow Meters

    • Continuous monitoring of system performance

Post-Treatment & Storage

  1. RO Product Water Storage Tank (capacity as per site requirement)

  2. UV Sterilizer / Ozone Disinfection (Optional)

    • Final microbial safety barrier

  3. Polishing Filter (Optional)

  • Enhances the taste and visual clarity of water

Working Principle

  • Raw water passes through sand and carbon filtration to stabilize turbidity and chemical load.

  • Pre-treated water is pressurized and fed to the RO membranes, where only pure water molecules pass through.

  • Treated permeate water is collected for consumption, while reject water carries away concentrated impurities.

Suitable Applications

  • Large factories & industrial units

  • Educational campuses & hostels

  • Mosques & religious complexes

  • Worker housing & labor camps

  • Residential colonies & community water points

  • Commercial food preparation zones

Key Advantages

  • High-volume, stable drinking water production

  • 2072 FRP vessel ensures strong pre-treatment performance

  • Reduced membrane fouling and pressure fluctuations

  • Long membrane life and lower maintenance frequency

  • Consistent water quality during peak demand hours

  • Suitable for continuous institutional operation

Operation & Maintenance

  • Periodic backwash of sand and carbon filters

  • Cartridge filter replacement as per pressure drop

  • RO membrane life is typically 2–3 years

  • CIP cleaning based on permeate flow and pressure trend

  • Routine monitoring of TDS, pressure, and flow rates

Design & Selection Guidelines

  • Raw water testing (TDS, iron, hardness, chlorine, turbidity) is mandatory

  • Pre-treatment upgrades (iron removal/softener) may be required for difficult raw water

  • Final performance depends on feed water quality and operating conditions

Standard Supply Scope

  • Skid-mounted RO plant with MS powder-coated structure

  • 2072 FRP pressure vessel with graded filter media

  • RO membranes with SS housing

  • High-pressure pump, gauges & flow meters

  • Cartridge filter housing & UV system (if included)

  • Electrical panel, valves, piping & fittings

  • Installation, commissioning & operator training

Reviews

There are no reviews yet.

Be the first to review “Reverse Osmosis (RO) Water Treatment Plant – 9000 GPD / 1500 LPH”

Your email address will not be published. Required fields are marked *

0
    0
    Your Cart
    Your cart is emptyReturn to Shop
    Scroll to Top